Tech Specs

Strom Auditorium Technical Specifications

Telephone Numbers:
207) 236-7800      Kailey Smith   (Auditorium Manager/Technical Director)
(207) 236-7800 ext. 3263       Shaunna Brown (rentals and scheduling)
(207)236-7813                      FAX

Directions and Parking:      Camden Hills Regional High School is located on the north side of Route 90 in Rockport. Maine, two miles east of Route17, one mile west of Route 1.   Ample parking is available.   Please call ahead to make arrangements for equipment load-in and parking for trucks and buses.

Seating Capacity:    816+ 10 wheelchair locations = 826

Venue Type:       Proscenium theater - no balcony.   Auditorium seating is American style with a raked floor.   See seating plan for more details.

Theater Dimensions:           
Proscenium: Height: 17'-0 " 
                       Width: 55'-6" maximum

Grid Height:         34'-9"

Maximum Trim Height: 30'-3"

Stage Depth: Plaster Line to upstage wall:     29'-6"

Center apron to back wall:             45'-6"

Center apron to house curtain:            16'

Stage Height:          3'-0" above house floor

Orchestra Pit Depth:      4'-6" below stage level

Load-in Door                       
Into building: 32" x 80" - larger if post(s) removed.

Onto stage: 8' x 12'

Stage Features:        
Full sized orchestra pit. 
Pit height is not moveable/adjustable

Proscenium opening is equipped with two tormentor                        panels that can reduce the opening to a minimum of 39'-0"

House curtain is rigged on lineset #2 and can be tabbed but not flown. The curtain is red velour.

There are no stage floor traps.

Dressing Rooms:          There are two dressing rooms located directly behind the stage on the same level off of the Black Box Theater.   Each room is equipped with a full-sized ADA compliant shower   and rest room, mirrors and counter for makeup.   Each room can accommodate approximately 8 performers. No "star" dressing rooms are available.   The Black Box generally handles any overflow.
              

Green Room:          The Black Box serves as the Green Room.  

Hospitality:          The Wave Cafe is available for food service.   Please contact  [email protected] for questions about catering services.

Technical Systems
Stage Lighting:
         
The system consists of 164 ETC Sensor 2.4kw dimmers

Control is an ETC Ion.   

Full inventory of ETC Source Four 750 

LED cyclorama stage wash and front light

Lighting positions and circuits are indicated on theater ground plan.     

The lighting control booth is located in the rear of the auditorium.

Stage Lighting Equipment Inventory

ITEM

NUMBER

MANUFACTURER

NOTES

Source 4 750
113
ETC

S4 10deg Barrels

6

ETC

S4 19 deg Barrels

19

ETC

S4 26 deg Barrels

49

ETC

S4 36 deg Barrels

44

ETC

S4 50 deg Barrels

12

ETC

S4 70 deg Barrels 2 ETC  

S4 90deg Barrels

4

Altman

750W

ETC Color Source Par

28

ETC

 

ETC Series 2 Lustr

5

ETC

 

Twofers

28

20A twistlock

Cable
2
ETC
100' 6 Circuit Multi-cable
4
100' (12/3)

 

4

50' (12/3)

15

25' (12/3)

10

under 10' (12/3)

Sidearms

11

Altman

12"

23

Altman

18"

13

Altman

24"

Cyc lights

7

Altman Spectra Cyc 200

 

Followspots

2

Great Performances FS400

1000 W

Template holders

35

City Theatrical

10A/ 25B

Iris kits

5

City Theatrical

Donuts

15

 

6"

Tophat

25

 

Full

Barndoors

20

Fresnel

14

PAR

Click here to download the 2010 Repertory Plot.pdf

House Lighting System:      
The system consists of both compact flourescent and                        incandescent lighting fixtures.
                   
All circuits are controlled by ETC Unison 2.4kw dimmers.
                   
Control of the system is available in the control booth and                backstage right.   Additional touch-pads are located by the house doors.
                   
Control for incandescent lights is also available via the stage lighting  system with DMX address # 193-203.

Sound
House Sound System:
 
While the house is large, the acoustics are excellent and                    sound reinforcement can be kept to a minimum.

The house sound system consists of 2 Danley Sound Labs SM961 
90 deg x 60 deg speakers and 2 Danley TH Mini-I 12" sub-woofers.
                   
The console is a 32 channel Yamaha  TF5

Stage foldback monitor system with two pairs of Speak-on connection points on stage driven by a 400w/ch QSC amp.   The signal is fed to the system from the aux outputs #1 and #2 on the house mix console. These outputs simultaneously feed back stage XLR-M connector point to allow the use of powered monitors and aux outputs #3 and #4 may be configured as additional monitor feeds via the patch bay and tie-line infrastructure.   Two E/V Force 12 passive monitors are available.

A complete two-channel Clear-Com intercom is available with          connection points throughout the theater and its supporting            spaces.   See below for inventory.

The sound console is located at the center of house.   

Sound equipment inventory:

Mixer:                        Yamaha TF 5 32 channel

Microphones:            
4 x Shure SLX wireless systems with SM58 Handheld wireless transmitters
1 x EV N/D 478 instrument mic
1 x EV N/D86 instrument mic
2 x EV N/D468 instrument mics
7 x Sennheiser 835 vocal mics
2 x Shure BG5.1 vocal mics
2 x Shure BG4.1 instrument mics
2 x Audio-Technica ATM33a instrument mics1 x Telex LT100 lavalier wireless vocal mic

Clear-Com:               
7 x headsets
7 x beltpacks (2 ch)

Rigging:                                -
The theater is not equipped with a grid iron, pin rails, or loading      rails. There are no provisions for spot line rigging.

Linesets are controlled from either back stage right or stage left
from stage level.

All linesets are 60' long with 8 hoist cables with 1,000 lb. t-track                                        guided arbors.

There are no provisions for rigging points for chain motors, etc.

Lineset Schedule:

  Lineset #

  Distance to plaster

  Purpose

  Notes

  Operated from

  --

  0'-0"

  Plaster Line

 

 

  1

  1'-1"

  Valance

  Red velour

  Dead hung

  2

  2'-0"

  House Curtain Traveler

  Red velour (dead hung)

  SL

  3

  3'-11"

  #1 Electric

  30 stage load circuits

  SL

  4

  6'-1 1/2"

  Movie Screen

  Permanently installed

  Dead hung

  5

  6'-6"

  #1 Legs

  Hung on swivel traveler

  Dead hung

  6

  7'-5"

  #1 Border

  B lack velour w/50% fullness

  SR

  7

  8'-5"

  General Purpose

 

  SR

  8

  9'-5"

  #2 Electric

  15 stage load circuits

  SR

  9

  10'-8"

  #2 Legs

  Hung on swivel traveler

  Dead hung

  10

  12'-1"

  #2 Border

  B lack velour w/50% fullness

  SL

  11

  13'-0"

  General Purpose

 

  SL

  12

  14'-0"

  Mid-stage Traveler

  Full stage black velour

  Dead hung

  13

  14'-10"

  #3 Electric

  15 stage load circuits

  SL

  14

  15'-7"

  #3 Legs

  Hung on swivel traveler

  Dead hung

  15

  16'-9"

  #3 Border

  B lack velour w/50% fullness

  SR

  16

  17'-9"

  General Purpose

 

  SR

  17

  18'-6"

  #4 Electric (Cyc Elec.)

  12 stage load circuits

  SR

  18

  19'-4"

  #4 Legs

  Hung on swivel traveler

  Dead hung

  19

  20'-11"

  Upstage Traveler

  Full stage black velour

  Dead hung

  20

  22'-11"

  White Leno Cyc

 

  Dead hung

  21

  23'-2"

  Cyc trip line set

  Rope set (no arbor)

  SR

 

Electrical Service:                   
400A 3-phase 208V service is available. There are also 2 single-        phase 208V x 50A range plug receptacles (NEMA #14-50).
No cam-locks are available

Hearing Assistance System:    
The house sound system is connected to a Williams Sound              hearing assistance system utilizing a Williams sound PPA-T4 FM      transmitter to a maximum of nine available Williams Sound PPA-R7-6 FM receivers.   The transmitter receives an audio signal from the house mixing console and broadcasts it via a low-power FM carrier signal.   The antenna is mounted on the front wall of the Control Booth.

House Video System:  
Projector- NEC 8000 lumen w-UXGA Laser Projector

A motorized projection screen (26'x17') is located at Lineset #4.   
The screen is controlled from off stage right and the Control Room.

Box Office:  
Box Office management staff are responsibility of the producing organization.   

Ushers:
It is the responsibility of the presenting organization to provide ushers (1 for every 100 audience members)