Strom Auditorium Technical Specifications
Telephone Numbers:
207) 236-7800 Kailey Smith (Auditorium Manager/Technical Director)
(207) 236-7800 ext. 3263 Shaunna Brown (rentals and scheduling)
(207)236-7813 FAX
Directions and Parking: Camden Hills Regional High School is located on the north side of Route 90 in Rockport. Maine, two miles east of Route17, one mile west of Route 1. Ample parking is available. Please call ahead to make arrangements for equipment load-in and parking for trucks and buses.
Seating Capacity: 816+ 10 wheelchair locations = 826
Venue Type: Proscenium theater - no balcony. Auditorium seating is American style with a raked floor. See seating plan for more details.
Theater Dimensions:
Proscenium: Height: 17'-0 "
Width: 55'-6" maximum
Grid Height: 34'-9"
Maximum Trim Height: 30'-3"
Stage Depth: Plaster Line to upstage wall: 29'-6"
Center apron to back wall: 45'-6"
Center apron to house curtain: 16'
Stage Height: 3'-0" above house floor
Orchestra Pit Depth: 4'-6" below stage level
Load-in Door
Into building: 32" x 80" - larger if post(s) removed.
Onto stage: 8' x 12'
Stage Features:
Full sized orchestra pit.
Pit height is not moveable/adjustable
Proscenium opening is equipped with two tormentor panels that can reduce the opening to a minimum of 39'-0"
House curtain is rigged on lineset #2 and can be tabbed but not flown. The curtain is red velour.
There are no stage floor traps.
Dressing Rooms: There are two dressing rooms located directly behind the stage on the same level off of the Black Box Theater. Each room is equipped with a full-sized ADA compliant shower and rest room, mirrors and counter for makeup. Each room can accommodate approximately 8 performers. No "star" dressing rooms are available. The Black Box generally handles any overflow.
Green Room: The Black Box serves as the Green Room.
Hospitality: The Wave Cafe is available for food service. Please contact [email protected] for questions about catering services.
Technical Systems
Stage Lighting:
The system consists of 164 ETC Sensor 2.4kw dimmers
Control is an ETC Ion.
Full inventory of ETC Source Four 750
LED cyclorama stage wash and front light
Lighting positions and circuits are indicated on theater ground plan.
The lighting control booth is located in the rear of the auditorium.
Stage Lighting Equipment Inventory
ITEM
|
NUMBER
|
MANUFACTURER
|
NOTES
|
Source 4 750
|
113
|
ETC
|
|
S4 10deg Barrels
|
6
|
ETC
|
|
S4 19 deg Barrels
|
19
|
ETC
|
|
S4 26 deg Barrels
|
49
|
ETC
|
|
S4 36 deg Barrels
|
44
|
ETC
|
|
S4 50 deg Barrels
|
12
|
ETC
|
|
S4 70 deg Barrels |
2 |
ETC |
|
S4 90deg Barrels
|
4
|
Altman
|
750W
|
ETC Color Source Par
|
28 |
ETC
|
|
ETC Series 2 Lustr
|
5
|
ETC
|
|
Twofers
|
28
|
|
20A twistlock
|
Cable
|
2
|
ETC
|
100' 6 Circuit Multi-cable
|
|
4
|
|
100' (12/3)
|
|
4
|
|
50' (12/3)
|
|
15
|
|
25' (12/3)
|
|
10
|
|
under 10' (12/3)
|
Sidearms
|
11
|
Altman
|
12"
|
|
23
|
Altman
|
18"
|
|
13
|
Altman
|
24"
|
Cyc lights
|
7
|
Altman Spectra Cyc 200
|
|
Followspots
|
2
|
Great Performances FS400
|
1000 W
|
Template holders
|
35
|
City Theatrical
|
10A/ 25B
|
Iris kits
|
5
|
City Theatrical
|
|
Donuts
|
15
|
|
6"
|
Tophat
|
25
|
|
Full
|
Barndoors
|
20
|
|
Fresnel
|
|
14
|
|
PAR
|
Click here to download the 2010 Repertory Plot.pdf
House Lighting System:
The system consists of both compact flourescent and incandescent lighting fixtures.
All circuits are controlled by ETC Unison 2.4kw dimmers.
Control of the system is available in the control booth and backstage right. Additional touch-pads are located by the house doors.
Control for incandescent lights is also available via the stage lighting system with DMX address # 193-203.
Sound
House Sound System:
While the house is large, the acoustics are excellent and sound reinforcement can be kept to a minimum.
The house sound system consists of 2 Danley Sound Labs SM961
90 deg x 60 deg speakers and 2 Danley TH Mini-I 12" sub-woofers.
The console is a 32 channel Yamaha TF5
Stage foldback monitor system with two pairs of Speak-on connection points on stage driven by a 400w/ch QSC amp. The signal is fed to the system from the aux outputs #1 and #2 on the house mix console. These outputs simultaneously feed back stage XLR-M connector point to allow the use of powered monitors and aux outputs #3 and #4 may be configured as additional monitor feeds via the patch bay and tie-line infrastructure. Two E/V Force 12 passive monitors are available.
A complete two-channel Clear-Com intercom is available with connection points throughout the theater and its supporting spaces. See below for inventory.
The sound console is located at the center of house.
Sound equipment inventory:
Mixer: Yamaha TF 5 32 channel
Microphones:
4 x Shure SLX wireless systems with SM58 Handheld wireless transmitters
1 x EV N/D 478 instrument mic
1 x EV N/D86 instrument mic
2 x EV N/D468 instrument mics
7 x Sennheiser 835 vocal mics
2 x Shure BG5.1 vocal mics
2 x Shure BG4.1 instrument mics
2 x Audio-Technica ATM33a instrument mics1 x Telex LT100 lavalier wireless vocal mic
Clear-Com:
7 x headsets
7 x beltpacks (2 ch)
Rigging: -
The theater is not equipped with a grid iron, pin rails, or loading rails. There are no provisions for spot line rigging.
Linesets are controlled from either back stage right or stage left
from stage level.
All linesets are 60' long with 8 hoist cables with 1,000 lb. t-track guided arbors.
There are no provisions for rigging points for chain motors, etc.
Lineset Schedule:
Lineset #
|
Distance to plaster
|
Purpose
|
Notes
|
Operated from
|
--
|
0'-0"
|
Plaster Line
|
|
|
1
|
1'-1"
|
Valance
|
Red velour
|
Dead hung
|
2
|
2'-0"
|
House Curtain Traveler
|
Red velour (dead hung)
|
SL
|
3
|
3'-11"
|
#1 Electric
|
30 stage load circuits
|
SL
|
4
|
6'-1 1/2"
|
Movie Screen
|
Permanently installed
|
Dead hung
|
5
|
6'-6"
|
#1 Legs
|
Hung on swivel traveler
|
Dead hung
|
6
|
7'-5"
|
#1 Border
|
B lack velour w/50% fullness
|
SR
|
7
|
8'-5"
|
General Purpose
|
|
SR
|
8
|
9'-5"
|
#2 Electric
|
15 stage load circuits
|
SR
|
9
|
10'-8"
|
#2 Legs
|
Hung on swivel traveler
|
Dead hung
|
10
|
12'-1"
|
#2 Border
|
B lack velour w/50% fullness
|
SL
|
11
|
13'-0"
|
General Purpose
|
|
SL
|
12
|
14'-0"
|
Mid-stage Traveler
|
Full stage black velour
|
Dead hung
|
13
|
14'-10"
|
#3 Electric
|
15 stage load circuits
|
SL
|
14
|
15'-7"
|
#3 Legs
|
Hung on swivel traveler
|
Dead hung
|
15
|
16'-9"
|
#3 Border
|
B lack velour w/50% fullness
|
SR
|
16
|
17'-9"
|
General Purpose
|
|
SR
|
17
|
18'-6"
|
#4 Electric (Cyc Elec.)
|
12 stage load circuits
|
SR
|
18
|
19'-4"
|
#4 Legs
|
Hung on swivel traveler
|
Dead hung
|
19
|
20'-11"
|
Upstage Traveler
|
Full stage black velour
|
Dead hung
|
20
|
22'-11"
|
White Leno Cyc
|
|
Dead hung
|
21
|
23'-2"
|
Cyc trip line set
|
Rope set (no arbor)
|
SR
|
Electrical Service:
400A 3-phase 208V service is available. There are also 2 single- phase 208V x 50A range plug receptacles (NEMA #14-50).
No cam-locks are available
Hearing Assistance System:
The house sound system is connected to a Williams Sound hearing assistance system utilizing a Williams sound PPA-T4 FM transmitter to a maximum of nine available Williams Sound PPA-R7-6 FM receivers. The transmitter receives an audio signal from the house mixing console and broadcasts it via a low-power FM carrier signal. The antenna is mounted on the front wall of the Control Booth.
House Video System:
Projector- NEC 8000 lumen w-UXGA Laser Projector
A motorized projection screen (26'x17') is located at Lineset #4.
The screen is controlled from off stage right and the Control Room.
Box Office:
Box Office management staff are responsibility of the producing organization.
Ushers:
It is the responsibility of the presenting organization to provide ushers (1 for every 100 audience members)
|